Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
0517-86918678
Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
Tel:0517-86918678
Fax:0517-86918679
Email:zhongweick@163.com
Post Encoding:211600

The electronic computer shielded cable

电子计算机屏蔽电缆.jpg
  • 电子计算机屏蔽电缆.jpg
Electronic computer shielded cable is used for power generation, metallurgy, petrochemical and other…

Description:

A, product characteristics and USES:
Electronic computer shielded cable is used for power generation, metallurgy, petrochemical and other industrial and mining enterprises and distributing system, computer system, signal transmission of the automation system and testing instruments, meters and other connection with multiple of shielded cable.
Second, the electronic computer shielded cable using features:
Working temperature: general type does not exceed 70 ℃, after the model 105 is highest do not exceed 105 ℃.
Minimum ambient temperature: fixed installation to 40 ℃ the fixed installation to 15 ℃
The rated voltage Uo/U: 300/500 v
The minimum bending radius: no armoured layer cable should be not less than 6 times of cable diameter
Layer with armored cable should be not less than 12 times of cable diameter
Three, computer shielded cable main technical indicators:

Performance of the projectunitTechnical indicators
Polyethylene insulationPVC insulated
Insulation resistance when 20 ℃As a line between the conductorsM Ω · km50025
Between the shielding line11
Capacitance (1 KHZ)Type 3pF/m75200
1 and 290
Capacitance unbalance (1 KHZ)pF/M1/
Inductive resistance thanCross sectionMu h/Ω20
20
25
35
20
20
25
35

0.5mm2
0.75mm2
1.0mm2
1.5mm2






Shielding inhibition coefficient or less
0.010.01
Test voltageV/1min10001000
Flame retardant
Comply with the requirements of 12666-90Comply with the requirements of 12666-90

Four, computer shielded cable type:


projectCode nameinstructions
Flame retardant code/
ZR
ZRA
ZRB
ZRC
The flame retardant can be omitted
Flame retardant
Grade A flame retardant
Class B fire retardant
Class C fire retardant
A series of codesDJThe electronic computer (including DCS system) and electric instrument
Insulation materialsY
V
D
W
polyethylene
Polyvinyl chloride (PVC)
Low smoke low halogen polyvinyl chloride (PVC)
Low smoke zero halogen polyvinyl chloride olefins
Shielding materialsP
P1
P2
P3
Copper wire braided
Tin plated copper wire weaving
Copper/polyester composite membrane
Aluminum/polyester composite membrane
Sheath materialY
V
D
W
Heat resistant polyethylene
Polyvinyl chloride (PVC)
Low smoke low halogen polyethylene
Low smoke zero halogen polyolefin
Armoring materials22Steel tape armoured
Conductor typeA
B
R
Single strand conductors
Seven strands of stranded conductor
More flexible conductor
specifications
Fill in the logarithmic x (unit some x conductor cross section)
Logarithmic N: 1, 2, 3,......19
Unit some n: 2, 3
S: conductor section 0.5, 0.75, 1.0, 1.5, was


Browse:
Return To The Top

分享到: