Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
0517-86918678
Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
Tel:0517-86918678
Fax:0517-86918679
Email:zhongweick@163.com
Post Encoding:211600

Electric contact pressure type thermometer

19电接点压力式指示温度计.jpg
  • 19电接点压力式指示温度计.jpg
WTZ-280 series Electric contact pressure type thermometer Suitable for the measurement of copper and…

Description:

Productoverview:
WTZ-280 series Electric contact pressure type thermometer Suitable for the measurement of copper and copper alloys do not corrode liquid, gas and steam temperature, and can reach or exceed a given value when the temperature signal, the electric contact pressure type thermometer can also be used as the temperature control circuit contact switch in the system. Anti-corrosion type adopts stainless steel material, the temperature measurement for neutral corrosive gas and liquid.

Two, work principle:
WTZ-280 series Electric contact pressure type thermometer The principle is the relation between evaporation of the liquid in the airtight temperature measurement system based on saturated vapor pressure and temperature, and temperature measurement. When the temperature felt when the temperature changes, sealed system to produce the corresponding saturated vapor pressure, caused by the change of the curvature of the elastic element, the free end displacement produced by the displacement amplification mechanism for gear indicator.
Three, application:
WTZ-280 series Electric contact pressure type thermometer Used in the production field of temperature automatic control and alarm. Can the liquid, steam and gas temperature measurement in various production processes of -80 in the range of -+500 DEG C. Suitable for neutral corrosive liquids and gases.
 WTZ-288, WTQ-288 <strong><strong><strong><strong><strong><strong><strong></strong></strong></strong></strong></strong></strong></strong>
Four, main features:
1, a temperature probe of small, high sensitivity, linear scale, long service life etc.;
2, with remote output resistance signal (PT100), shock resistance, corrosion resistant function and large power switch signal etc.;
3, structure and international similar products, can replace imported;
4, electric contact transmission.
Five, technical parameters:
1, time constant: 15S (steam) 30S (gas)
2, contact capacity: 10VA (no sense) Zui high voltage: AC 220V, upper and lower limit contact.
3, the working environment temperature: 10~+55 degrees Celsius
4, indicating the accuracy: 1.5 (range part requirements) 
 WTZ-288, WTQ-288 <strong><strong><strong><strong><strong><strong><strong></strong></strong></strong></strong></strong></strong></strong>
Sixth, external reference line:
WTZ (Q) -280 series of thermometers on the lower limit of the electrical device contact capacity is 10VA, so each user to solve contact power amplification problem, for the convenience of users, we will have the power amplifier circuit and the arc extinguishing effect of the anti vibration is recommended as follows
Note: the line power amplifier circuit in the lower contact as long as the contact time, the coil loop will enter the self-locking state, and only when the upper contact action of a lower exit loop can be self-locking, so as to realize the protection requirements of electric contact.

Table seven parameters:

Model

function

Dial diameterMm

As to the

Case Material

WTZ-280

WTQ-280

Indicating type

One hundred

Radial (hanging)

Bakelite

Eighth, measuring range:

measuring range

WTZ-280

WTQ-280

-20~60 ; 0~100 ; 20~120 ; 60~160 ; 40~60; 0~50 ; 0~120 ;

0~200 ; 0~250 ; 0~300 ; 0~400 ; 0~500 ;0~600

The temperature package insert depth

150~280 (long tail 12M ) 200~300 (tail length > 12M )

Temperature package material

Phi 8 ; Phi 10 ;  Phi 13 ; Phi 14 Brass, Phi 8 ; Phi 10 ;  Phi 13 ; Phi 14 Stainless steel pipe

Capillary material

Copper capillary  Plastic coated capillary  Stainless steel capillary

Installation mode

WTZ-280

M27*2 Movable external thread

The material of copper, iron, stainless steel

WTQ-280

M33*2 Movable external thread

Long tail

1M~20M > 20M Special processing

technical parameter

Precision grade 1.5/2.5  Contact capacity: 220V/1A (non inductive load 10VA )

The size of the mounting hole

4 "- 6" - Phi Phi 118mm 158mm

Nine, Design selection and ordering information:
1, please indicate the type, name, thread size, measurement range, precision grade.
2, if you have special requirements, please specify when ordering. 
Eighth, customer service service commitment:
1, the company sold in great pressure Thermometer series The product within twelve months of quality problems, responsible for free maintenance.
2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.



Browse:
Return To The Top

分享到: