Anti-corrosion type double metal thermometer

5防腐型双金属温度计02.png
  • 5防腐型双金属温度计02.png
WSSF series Anti-corrosion type double metal thermometer Is a kind of field measurement, suitable fo…

Description:

Productoverview:
WSSF series Anti-corrosion type double metal thermometer Is a kind of field measurement, suitable for low temperature detection of industrial instrument can be used to directly measure the gas, liquid and steam temperature.Electric contact bimetallic thermometer can exceed the given values in the temperature, automatically sends out control signal to cut off power supply or alarm.
Double metal thermometer has advantages of no mercury damage, easy reading, sensitive reaction and solid proof, can replace the industrial glass mercury thermometer, widely used in industrial and scientific research departments.Anticorrosion type instrument shell using Aluminum Alloy three spray paint or coating, protection tube, connecting columns made of 316L material, the connecting part adopts the sealing pad, temperature measurement can be applied in the most corrosive medium, gas.
Two, work principle:
WSSF series Anti-corrosion type double metal thermometer Is the principle of expansion work in varying degrees of temperature change when using two different metals. Industrial use of double metal thermometer main element is one with two or more metal sheet laminated together to form a multilayer metal sheet. In order to improve the measurement sensitivity of double metal thermometer, usually made of sheet metals of spiral shape. When the multilayer metal sheet temperature changes, each layer of metal expansion or shrinkage range, so that the spiral rolled up or loosen. Since the end of the spiral coil is fixed and the other end and a pointer can rotate freely. Therefore, when the feeling of double sheet metal to temperature changes, in a pointer to the circular indexing on the gauge indicates the temperature to.
Three, application:
WSSF series Anti-corrosion type double metal thermometer The shell adopts Aluminum Alloy three spray paint or coating, protection tube, connecting columns made of 316L material, the connecting part adopts the sealing pad, temperature measurement can be applied in the most corrosive medium, gas.
Four, main features:
1, the scene display temperature, convenient safe and reliable, long service life;
2, a variety of forms, can meet different requirements. Victims of mercury free, easy reading, strong shock.
3, the protection pipe of 1Gr18Ni9Ti stainless steel and two molybdenum titanium, pressure, strong corrosion resistance.
4, core pulling type thermometer can not stop short time maintenance or replacement of movement.
5, integrated with axial type, radial type, 135 type, universal type, complete varieties, suitable for various on-site installation need.
Five, technical parameters:
1, the implementation of standards: JB/T8803-1998 GB3836-83;
2, dial diameter: 60100150;
3, accuracy: (1, 1.5);
4, thermal response time: less than 40S;
5, protection grade: IP55;
6, adjust the angle error: adjustment angle error should not exceed the range of 1%;
7, return difference: double metal thermometer to the difference should be less than the absolute value of the basic error limit;
8, repeat: double metal thermometer repeatability limit should be less than the absolute value of basic error of 1/2.
Six, matters needing attention:
1, in storage, installation, use and transport process, to avoid the collision protection tube, prohibit the protection tube bending and deformation.
2, installation, non twist instrument shell.
3, the instrument shall work normally in the -30 to 80 DEG C ambient temperature.
4, the instrument can often work in the temperature scale range 1/2 ~ 3/4.
5, the protective tube immersionmedium measured in length must be greater than the length of the sensing element, this is done in order to ensure the accuracy of measurement.
6, do not use media exposure in measuring container.
7, the use of the process should pay attention to check in time, probably in about 6 months.


Seven, temperature range:

The measuring range of C

Applicable scope

Industrial and commercial

Laboratory and small

-80 ~ +40

B.

B.

-40 ~ +80

B.

B.

0~50

B.

B.

0~100

B.

B.

0 ~ 150

B.

B.

0 ~ 200

B.

B.

0 ~ 300

B.

B.

0~400

B.

B.

0~500

B.

B.

Eight, shape and size:

form

A

B

C

E

L

D

Axial type

Sixty-five

Twenty-three

Seventy-three

-

Seventy-five
One hundred
One hundred and fifty
Two hundred
Three hundred
Four hundred
Five hundred
Seven hundred and fifty
One thousand

Phi 6
Phi 8
Phi 10

One hundred and five

Twenty-three

Seventy-three

-

One hundred and fifty-five

Twenty-three

Seventy-three

-

Radial type

Sixty-five

Fifty

One hundred and ten

Thirty-four

One hundred and five

Fifty

One hundred and ten

Thirty-four

One hundred and five

Fifty

One hundred and ten

Thirty-four

135 degrees to type

One hundred and five

Twenty-three

Eighty-five

-

One hundred and fifty-five

Twenty-three

Eighty-five

-

Universal type

One hundred and five

Twenty-three

One hundred and seventy-eight

One hundred and twenty

One hundred and fifty-five

Twenty-three

One hundred and seventy-eight

One hundred and twenty

Nine, technical data sheet:

Serial number

Model

structural style

Case diameter

Protection tube diameter

The protective tube length L

Standard installation thread

The temperature range C

One

WSSF-401

Angle type

Phi 126

Phi 10

Seventy-five
One hundred
One hundred and twenty
One hundred and fifty
Two hundred
Two hundred and fifty
Three hundred
Four hundred
Five hundred
Seven hundred and fifty
One thousand
One thousand and two hundred
One thousand and five hundred
One thousand seven hundred and fifty
Two thousand
Two thousand and five hundred

M27 * 2

-60 - +40
-40 - +60
-20 - +80
0 - 50
0 - 100
1 - 120
0 - 150
0 - 200
0 - 300
0 - 400
0 - 500
0 - 600

Two

WSSF-411

Straight

Phi 126

Three

WSSXF-401

Electric contact angle

Phi 126

Four

WSSXF-411

Straight type electric contact

Phi 150

Five

WSSF-501

Angle type

Phi 166

Six

WSSF-511

Straight

Phi 166

Ten, the selection of encoding:

Serial number

category

Specifications

Explain

WSS

F

Anti-corrosion type

Double metal thermometer (Zhongwei control)

Dial diameter

-3


Phi 60

-4


Phi 100

-5


Phi 150

Dial form

Zero


The axial (straight)

One


Radial (angle)

Two


135 degrees to (an obtuse type)

Eight


Universal (angle adjustable type)

Fixed form

Zero


No fixed device

One


Movable external thread

Two


The movable internal thread

Three


Fixed thread

Four


Fixed flange

Five


Card set screw

Six


Sleeve flange

Type of protection

-


Ordinary type

W


Type of protection

F


Anti-corrosion type

Eleven, design and ordering:

Please provide the type, dial diameter, precision grade, fixed form, the range of temperature measurement, protection material, pipe length or depth of insertion.

Customer service service commitment:
1, my company sold Zhongwei Thermometer series The product within twelve months of quality problems, responsible for free maintenance.
2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.


Browse:
Return To The Top

分享到: