Universal type double metal thermometer

5万向型双金属温度计.PNG
  • 5万向型双金属温度计.PNG
WSS series Universal type double metal thermometer Compared with the domestic similar products: inst…

Description:

Productoverview:
WSS series Universal type double metal thermometer Compared with the domestic similar products: instrument precision grade 1.0, instrument shell made of anti-corrosion materials, its temperature can be as high as 200 c, Zui low -40 C. Flange type structure, double sealing ring, the anticorrosion, good waterproof performance. The protective tube welded by automatic argon protection tube, solid weld, small intergranular corrosion. The dial is aluminum oxide printing plate, clear surface styling. For the adjustable pointer.
Two, work principle:
WSS series Universal type double metal thermometer Is the principle of expansion work in varying degrees of temperature change when using two different metals. Industrial use of double metal thermometer main element is one with two or more metal sheet laminated together to form a multilayer metal sheet. In order to improve the measurement sensitivity, usually made of sheet metals of spiral shape. When the multilayer metal sheet temperature changes, each layer of metal expansion or shrinkage range, so that the spiral rolled up or loosen. Since the end of the spiral coil is fixed and the other end and a pointer can rotate freely. Therefore, when the feeling of double sheet metal to temperature changes, in a pointer to the circular indexing on the gauge indicates the temperature to. The measuring range of this instrument is about 200~650 DEG C, allowable error are 1% of range scale. The use of glass liquid thermometer thermometer and a rod is similar, but can be used in mechanical strength under the condition of higher requirements.
Three, application:
WSS series Universal type double metal thermometer It can directly measure the production process in a variety of -80 to +500 DEG C range of liquid, steam and gas temperature. Widely used in petroleum, chemical, machinery, shipbuilding, power, textile, printing and dyeing industry and scientific research departments.
Four, main features:
1, the scene display temperature, convenient safe and reliable, long service life;
2, a variety of forms, can meet different requirements. Victims of mercury free, easy reading, strong shock.
3, the protection pipe of 1Gr18Ni9Ti stainless steel and two molybdenum titanium, pressure, strong corrosion resistance.
4, core pulling type thermometer can not stop short time maintenance or replacement of movement.
5, integrated with axial type, radial type, 135 type, universal type, complete varieties, suitable for various on-site installation need.
Five, technical parameters:
1, the implementation of standards: JB/T8803-1998 GB3836-83;
2, dial diameter: 60100150;
3, accuracy: (1, 1.5);
4, thermal response time: less than 40S;
5, protection grade: IP65;
6, adjust the angle error: adjustment angle error should not exceed the range of 1%;
7, return difference: double metal thermometer to the difference should be less than the absolute value of the basic error limit;
8, repeat: double metal thermometer repeatability limit should be less than the absolute value of basic error of 1/2.

Six, Matters needing attention:
1, in storage, installation, use and transport process, to avoid the collision protection tube, prohibit the protection tube bending and deformation.
2, installation, non twist instrument shell.
3, the instrument shall work normally in the -30 to 80 DEG C ambient temperature.
4, the instrument can often work in the temperature scale range 1/2 ~ 3/4.
5, the protective tube immersionmedium measured in length must be greater than the length of the sensing element, this is done in order to ensure the accuracy of measurement.
6, do not use media exposure in measuring container.
7, the use of the process should pay attention to check in time, probably in about 6 months.

Seven, temperature range:

The measuring range of C

Applicable scope

Industrial and commercial

Laboratory and small

-80 ~ +40

B.

B.

-40 ~ +80

B.

B.

0~50

B.

B.

0 ~ 100

B.

B.

0 ~ 150

B.

B.

0~200

B.

B.

0~300

B.

B.

0~400

B.

B.

0~500

B.

B.

Remarks:
One The insertion depth of the thermometer, L Must be greater than Lmin , L Alternative series: One hundred , One hundred and fifty , Two hundred , Two hundred and fifty , Three hundred , Four hundred , Five hundred , Seven hundred and fifty , One thousand , One thousand two hundred and fifty , One thousand and five hundred , Two thousand So, also can be customized according to user needs.
Two And the protective tube diameter Phi 6 , Phi 8 The series of thermometers, the time constant is less than FortySecond, diameter Phi 10 When the time constant is less than Thirty Seconds.
Three Protect the stainless steel tube 1Cr18Ni9Ti Manufacturing, at room temperature under high working pressure is Zui 6.4MPa .

Eight, shape and size:

structural style

A

B

C

E

L

D

The axial type double metal thermometer

Sixty-five

Twenty-three

Seventy-three

-

Seventy-five
One hundred
One hundred and fifty
Two hundred
Three hundred
Four hundred
Five hundred
Seven hundred and fifty
One thousand

Phi 6
Phi 8
Phi 10

One hundred and five

Twenty-three

Seventy-three

-

One hundred and fifty-five

Twenty-three

Seventy-three

-

The radial type double metal thermometer

Sixty-five

Fifty

One hundred and ten

Thirty-four

One hundred and five

Fifty

One hundred and ten

Thirty-four

One hundred and five

Fifty

One hundred and ten

Thirty-four

135 degrees to type double metal thermometer

One hundred and five

Twenty-three

Eighty-five

-

One hundred and fifty-five

Twenty-three

Eighty-five

-


One hundred and five

Twenty-three

One hundred and seventy-eight

One hundred and twenty

One hundred and fifty-five

Twenty-three

One hundred and seventy-eight

One hundred and twenty

Nine, the specific model name that said:

Model

Measuring range

Precision grade

Protection tube material

Specifications

Fixed form

D

L

WSS-480

-80 ~ +40
-40 ~ +80
0 ~ 50
0 ~ 100
0 ~ 150
0 ~ 200
0 ~ 300
0~400
0~500

One point five

1Cr18Ni9Ti
Three hundred and four
Three hundred and sixteen
316L
Hastelloy C-276

Phi 100

Seventy-five
One hundred
One hundred and fifty
Two hundred
Three hundred
Four hundred
Five hundred
Seven hundred and fifty
One thousand

No fixed device

WSS-580

Phi 150

WSS-481

Phi 100

Movable external thread

WSS-581

Phi 150

WSS-482

Phi 100

The movable internal thread

WSS-582

Phi 150

WSS-483

Phi 100

Fixed thread

WSS-583

Phi 150

WSS-484

Phi 100

Fixed flange

WSS-584

Phi 150

WSS-485

Phi 100

Card set screw

WSS-585

Phi 150

WSS-486

Phi 100

Sleeve flange

WSS-586

Phi 150

Ten, the selection of encoding:

Serial number

WSS


Double metal thermometer (Zhongwei control)

Dial diameter

-3


Phi 60

-4


Phi 100

-5


Phi 150

Dial form

Zero


The axial (straight)

One


Radial (angle)

Two


135 degrees to (an obtuse type)

Eight


Universal (angle adjustable type)

Fixed form

Zero


No fixed device

One


Movable external thread

Two


The movable internal thread

Three


Fixed thread

Four


Fixed flange

Five


Card set screw

Six


Sleeve flange

Type of protection

-


Ordinary type

W


Type of protection

F


Anti-corrosion type

The selection of examples:
100, dial diameter, temperature range of 0~400 DEG C, level 1.5, rotatablemale thread M27 * 2 450mm, length WSS-481, 0~400 C, L=450, M27 * 2, 1.5.

Eleven, ordering:
Please provide the type, dial diameter, precision grade, fixed form, the range of temperature measurement, protection material, pipe length or depth of insertion.
Customer service service commitment:
1, my company sold Zhongwei Thermometer series The product within twelve months of quality problems, responsible for free maintenance.
2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, 48 hours outside users arrive at the scene.


Browse:
Return To The Top

分享到: