Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
0517-86918678
Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
Tel:0517-86918678
Fax:0517-86918679
Email:zhongweick@163.com
Post Encoding:211600

High temperature type pressure transmitter

C高温型压力变送器316.jpg
  • C高温型压力变送器316.jpg
ZW316 seriesHigh temperature type pressure transmitterPicked from the international famous company h…

Description:

ZW316 seriesHigh temperature type pressure transmitterPicked from the international famous company high accuracy high stability of pressure sensor components, through the high reliability of amplifying circuit and precise temperature compensation, transforms the pressure of tested medium into 4 ~ 20 madc, 0 ~ 5 VDC, 0 ~ 1 ovdc and standard electrical signals such as 1 ~ 5 VDC.High quality sensors, exquisite packaging technology and improve the assembly process to ensure that the product is of superior quality and performance.The product has a variety of interface form and multiple electrodes, to meet the needs of customers, zui large extent are applicable to all measurement and control equipment systems.

Second, the working principle:

ZW316 series high temperature type pressure transmitter using diffusion and ion implantation technology form resistance and connect ChengHui stone bridge, with micro mechanical processing technology in the electrical bridge formation pressure sensitive film.When the pressure on the diaphragm, resistance to change and produce a is proportional to the applied pressure of the linear output signal.We are on the wheatstone bridge with dc power supply, can produce a dc voltage signal output.After a second crossover, realizes the two wire system 4 ~ 20 ma output.

Applications:

ZW316 series high temperature type pressure transmitter components and parts are imported high quality silicon diffusion type, ceramic pressure sensor as a sensitive element, using special integration module, fine nonlinear compensation of temperature drift, zero, and, for the liquid, gas, steam medium pressure changes such as the accuracy of the measuring and transmitting.

Four, the main features:

1, good stability, full, zero long-term stability can amount to 0.2% FS/year.Within the scope of the compensation temperature 0 ~ 70 ℃, the temperature drift less than 0.2% FS, throughout the allowed working temperature range is less than 0.5% FS.

2, with reverse protection, current limiting protection circuit, when the installation is negative answer the reverse will not damage the transmitter, abnormal transmitter automatically when current limit within 35 ma.

3, solid structure, no moving parts, high reliability, long service life.

4, from wind to water, oil can be high precision measurement, not affected by the quality of the measured medium size.

5, easy installation, simple structure, economy is durable.

Five, the technical parameters:

Measuring range: 0-10 kpa ~ 0 to 40 mpa;

Z big overload: standard range 2 times;

Pressure form: pressure, differential pressure table;

F. S level of accuracy: 0.5%;

The power supply voltage: 24 VDC;

Load resistance: 500 Ω or less;

Measuring the pressure of medium: steam or gas, liquid;

Long term stability: plus or minus 0.2% f. S/year;

Environmental relative humidity: 0 ~ 95%;

Compensation temperature: 0 ~ 70 ℃;

Working temperature: - 10 ~ 70 ℃.

Structure features:

Shell: all stainless steel body;

The main structure material: 2.5 Mo ni cr - 12-31618;

Pressure interface: M20 x 1.5;

1 kg weight: regular, belt type header 1.2 kg.

Six, the debugging method:

Open the HSM joint, unscrewed the stainless steel pipe, can see zero and full range resistor, an external power supply and the current meter (0.2 or above), standard can be adjusted, the steps are as follows:

1 in the absence of pressure transmitter, adjust the zero resistor, make the output current of 4 ma,

2 pressure transmitter to full scale, adjust the full range resistor, make the output current of 20 ma,

Three steps above two or three times repeatedly, until the signal is normal.

The four adjustment, tighten the protection cover.

Seven, note:

1, who supply products with instruction manual and the certificate of approval, including product number, technical parameters, production date, etc., please check carefully, lest use wrong.

2, do not direct extrusion transducer diaphragm with hard object, so as not to damage the transmitter.

3, when installation should be according to the product connection method and the thread type, check whether the interface is consistent with the product interfaces, connection should be tighten slowly when, can't add torque directly to the transmitter on the shell, only on the pressure of the interface the six-party should be added.

4, connect the power supply shall be in strict accordance with my company connection wiring instructions.

5, side to overload pressure shall not exceed 200% of the range.

Found in 6, the use of exception, should turn off the power and stop using, check, or directly to our technical department.

7 should be restored the original packaging, transportation, storage, stored in a cool, dry and ventilated warehouse.

8, replacement for one year.

Eight, selection of code:

ZW316

The pressure transmitter (wei measurement and control)


code

Scale range

A

0-5KPa-20KPa

B

0-20KPa-70KPa

C

0-70KPa-350KPa

D

0-200KPa-700KPa

E

0-0.7MPa-3.5MPa

F

0-2.0MPa-7MPa

G

0-7MPa-35MPa

H

0-20MPa-100MPa


code

Precision grade

0.1%

0.25%

0.5%


code

The output code

E

4-20 madc second line

K

0-10mA

M

The user agreement


code

Pressure connection

R

Standard (M20 x 1.5)

P

Flush the membrane

O

According to the size of the user processing


code

Electrical connections

C1

Cable type derivation (degree of protection IP65)

C2

Plug type connection type (degree of protection IP65)

M

The user agreement


code

options

Lm

Cable lead length (m)

i

The Ann type ia Ⅱ CT6

T

Marine type

Z

Crossover sub

S

Radiator (M20 x 1.5, medium temperature < 200 ℃)

C

Choose ceramic sensors

F

Used for pressure measurement

A

Used for pressure measurement

Y

The user agreement

Mounting bracket installation accessories...........................G

Explosion-proof cable gland

External thread M20 x l. 5...R

User selects the attachments, please parentheses after selection code

Note the code to the attachment

Such as:

ZW316□□□□□□□□

When ordering, please specify the name of the measured medium, working pressure, medium temperature, measuring range, etc.If you have any questions, please call the sales manager of the company or technical contact.

After-sales service commitment:

1, our company sold 316 series product quality problem within 12 months, responsible for free maintenance.

2, the warranty period, any quality problems such as the products of our company, my company is responsible for free repair or replacement.

3, the warranty period, such as user improper use, damaged products, my company is responsible for the maintenance, charge damage parts cost.

4, after the warranty period appear quality problem, my company is responsible for the maintenance, charge damage parts cost.

5, such as user need to my company site services, to users in the province I company service personnel to reach the site within 12 hours, fujian association of foreign languages and user reach the site within 48 hours.


Browse: