Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.

Boiler steam drum two-color level gauge

15锅炉汽包双色液位计01.jpg
  • 15锅炉汽包双色液位计01.jpg
Boiler steam drum two-color level gauge of direct observation of water (liquid).Steam and water inte…

Description:

Products overview:

ZW - B49H seriesBoiler steam drum two-color level gaugeIs after all the joint efforts of the scientific research personnel and further developed a new type of product, the luminous intensity is higher, further visual distance, scale label more clearly, the display area is big, product series;Liquid level display using high brightness LED double color light-emitting tube, level of red, green light shows, observation distance of 60 m during the day, night can reach above 200 m.Is installed on the boiler or other media for an instrument on the liquid container.

Second, the working principle:

ZW series - B49H boiler steam drum structure principle of two-color level gauge is a water level measurement equipment, installed on the boiler, direct observation water level.Two-color level meter through the optical principle of boiler water, steam, as suggested by the part are colored.Steam red, green water, steam red aqua green, steam full full red, full of green water, changing with water level automatic successive, is reliable monitoring of boiler water level, guarantee the safe operation of the boiler water level measurement.

Double color gauge connected to upper and lower valve, drain valve connected to the valve, the upper and lower valve flange connected to the boiler flange.In working status, the upper and lower valve is open (drain valve is closed at this time), so water level gauge and boiler constitute a connected circuits.The water level gauge of liquid level height is the water level in the boiler.

Applications:

ZW series - B49H boiler steam drum two-color level gauge equipped with limit switches, can realize the liquid level, the lower limit alarm and control;Equipped with liquid level transmitter, liquid level signal can be converted into 4 ~ 20 madc analog signal, realizing remote detection, indicating, recording, and control, also direct communication with the computer system.This series products are widely used in electric power, metallurgy, petroleum, chemical industry, environmental protection, shipbuilding, construction and other industries the production process, all kinds of tower, tank and boiler liquid level measurement and control of the equipment.

Four, the main features:

1, steam aqua green red, show clear, viewing Angle is large, visual distance.

2, body selects the high quality stainless steel manufacturing, containers within the medium level gauge display device with no contact, no leakage, suitable for use one, two, three types of pressure vessel.And internal containers of flammable, toxic and corrosive medium safe and reliable.

3, display range, design pressure is high, wide use.

4, sealing surface 95% less than the traditional glass level gauge funnelled, overcome the industries of petroleum, chemical, pharmaceutical and other pressure vessels and run, run, drip, leak of liquid level meter connections such as weak links.

5, if users need, 1:1, 1:2, 1:4 without transmitting far eastone direct display liquid level;Can form a complete set of standard 4-20 ma output signal, the implementation level of remote display and containers of level of centralized monitoring and control;Can realize the water level automatic adjustment, chain safeguard.

Five, the technical parameters:

1, vertical installation: (zui big deviation for 30 or less);

2, measuring range: 0-150-6000 - mm (greater than 6000 mm negotiable order);

3, medium density: 0.4 to 2.0 g/cm <;

4, work temperature: - 50-400 ℃;

5, follow the speed: 0.08 m/s or less;

6, float material: 304, PTFE / 304 outside the village, PTFE, aluminum, titanium,

7, the LED display: low light type, highlighting, fog light scattering three optional;

8, leading tube material: 304;1 cr18ni9ti;316 l;304 of PTFE lining;Titanium;PP;PTFE (polytetrafluoroethylene)

9, connecting flange: DN15 ~ ((HG20592-97 flange standard), high voltage side type level gauge the HG20595-97 wonderful butt connecting flange standard;

10, flange material: carbon steel, 304, 316 l

11, power supply voltage: DC24V, AC36V, AC220V;

12, accuracy, or 10 mm;

13, working pressure: 0.1 ~ 10 MPa.

14, environmental vibration: frequency of 25 hz or less amplitude of 0.5 mm or less;

15, medium viscosity: Pa 0.4 or less) S;

16, drain valve, stainless steel ball valve, needle valve

17, the main pipe diameter: "¢57, 48, ¢¢62 mm.

Six, choice of additional features:

Limit switch:

1, the normally open type: above stations were closed;

2, normally closed type: above the alarm off;

3, switch capacity: 250 vac1a 250 vac 0.3 A (resistance);

4, switch life: 1 x 105 times;

5, liquid level transmitter: output current: 4 ~ 20 madc (two-wire system);

6, resolution: + / - 1 cm;

7, load resistance: 500 Ω (24 VDC power supply);

8, transmitting distance: 3000 m;

9, working power supply: 12 ~ 36 VDC;

Intelligent liquid level transmitter:

1, the output type: 4 ~ 20 madc;

2, resolution: 0.1% F.S.

3, load resistance: 0 ~ 36 VDC;

The installation location:

According to the installation position can be arbitrary change:

1, on the left side of the installation;

2, on the left side of the 600 installation;

3, standard installation;

4, the right side of the 600 installation;

5, the right side of the installation.

Seven, installation, use:

1, the hydraulic pressure meter flange and container seal on the flange clamp connection is good, screw down the bolt.

2, sensors, drain flange opening, in the float.Note: the float magnet steel end up, not the horse.

3, under the sensor drain flange, install a DN15 valve, with the original liquid level meter and drain pipe connected.

4, connect the power and input power AC36V insert AC220V power (or diameter), will the level to facilitate observation location.

5, open the valve on the first, and then slowly open the valve, especially the level meter used in high pressure, injection pressure ratio slowly, in case of float suddenly compression damage slowly into the sensor, make medium to observe the liquid level, according to the change from red to green one.

6, sewage, water, observe whether water level display, high and low water level alarm is normal, without abnormal phenomenon, can be put into use.

Eight, note:

1, form a complete set of instruments and accessories details see instruction corresponding instrument accessories.

2, in order to prevent lost or move far float up and down in the process of damage, with the level of correction magnetic steel factory supporting color logo (attached) will be on the outside of main pipe magnetic float.So after I receive my product or installation, please make correction magnets, so that float can move up and down with the liquid level, if the color is not consistent, before use available correction magnets which have suitable absorption, instrument can work normally.

3, level gauge after the installation, need correction magnets, the magnetic leads to a double column, so it shows zero the following red, zero or more display for the green.

4, level gauge according to user needs with heating jacket or electric heating device, such as user did not select this option when you order it, and after installation to using trace pipe road, and the mixed heating device of temperature should not exceed rated temperature of the liquid level gauge.

5, liquid level meter in travel, should first open the liquid pipe valves, and then, under the long open liquid pipe valve, let the liquid medium smoothly into the main pipe, avoid the liquid medium with float rise sharply, causing magnetic turn column flip failure or disorderly (if encounter the phenomenon, can use magnets to correction).

Nine, selection of code:

Generation of no.

In the boiler steam drum two-color level gauge (wei measurement and control)

ZW-B49X

Instrument material

4

304 stainless steel

6

316 stainless steel


Code name

The output signal

B0

The LED instructions given

B1

LED instructions given + 4 ~ 20 ma

B2

LED instructions given + alarm output

B3

LED instructions given + 4 ~ 20 ma + alarm output


Code name

Flange spacing

twenty

□□□mm


Code name

The flange size and standard

DN

The default size of flange for DN25, other requirements put forward when you order it


Code name

Explosion-proof requirements

There is no

No explosion-proof requirements

B

Explosion-proof type


Code name

Additional features

J1

With steam heating jacket

J2

With liquid level display

J3

Other (note)

Note: when ordering please indicate the medium temperature, medium density, working pressure, measuring range, standard flange, sensor measuring pipe material.If you have special request. When ordering, please specify.

Ten, when placing order, please provide the following parameters:

1, model specifications;ZW - B49H series;

2, the name of the measured medium, medium density: if you don't know the density, can tell us the name of the medium.

3, instrument measuring range: can also be referred to as the nominal length, namely the center distance of two flanges;

4, work stress: the highest stress;

5, working temperature: measuring the temperature of the liquid;

6, material requirements: liquid material;

7, whether matching supply flange, bolts, nuts, valves, fittings, such as sealing washer;

8, flange standard: nominal size of the flange, flange is 3/4 "or the most used DN25.

After-sales service commitment:

Level 1, I companies sell products within twelve months appear quality problem, is responsible for free maintenance.

2, the warranty period, any quality problems such as the products of our company, my company is responsible for free repair or replacement.

3, the warranty period, such as user improper use, damaged products, my company is responsible for the maintenance, charge damage parts cost.

4, after the warranty period appear quality problem, my company is responsible for the maintenance, charge damage parts cost.

5, such as user need to my company site services, to users in the province I company service personnel to reach the site within 12 hours, fujian association of foreign languages and user reach the site within 48 hours.


Browse:
Return To The Top

分享到: