Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.

Pulse radar level gauge

6脉冲雷达液位计601.jpg
6脉冲雷达液位计602.jpg
6脉冲雷达液位计603.png
6脉冲雷达液位计604.png
6脉冲雷达液位计605.PNG
6脉冲雷达液位计606.png
  • 6脉冲雷达液位计601.jpg
  • 6脉冲雷达液位计602.jpg
  • 6脉冲雷达液位计603.png
  • 6脉冲雷达液位计604.png
  • 6脉冲雷达液位计605.PNG
  • 6脉冲雷达液位计606.png
Pulse radar level meter using advanced radar measurement technology, with its excellent performance,…

Description:

Products overview:

ZWRD600 seriesPulse radar level gaugeBy microwave pulse measurement method, and can be within the scope of industrial frequency band is normal, low beam energy, can be installed on a variety of metals, non-metallic, container or the pipe for liquid, paste, and granular material level for non-contact continuous measurement.Applicable to the dust, change of temperature, pressure, and presence of inert gas and steam.Radar level meter and environment are no harm to human body, but also has not influenced by the proportion of medium, not affected by dielectric constant change, do not need to live the advantages of school adjustment, both for industrial needs, or the consideration of economic material benefit to customers, is a good choice.

Second, the working principle:

ZWRD600 series pulse radar level meter is the measuring instrument based on the principle of time travel, very low energy is emitted by a very short microwave pulse by transmitting and receiving antenna system.Radar wave are running at the speed of light.Running time can be transformed into material level signal by electronic parts.Probe a high-frequency pulse and probe the conduction along the cable type or rod type, when the pulse in the material surface reflected by the receiver inside the instrument, and the distance signal is transformed into material level signal.A special type of time extension method can guarantee the stability of a very short period of time and accurate measurement.Even if the condition is relatively complex, false echo, with zui new microprocessor technology and debug software can accurately analyze the level of the echo.

The input

Antenna receiving the reflected microwave pulse and sending them to the electronic circuit, microprocessor to signal processing, identify the micro pulse produced by the echo in the material surface.Correct echo signal recognition completed by intelligence software, precision can reach millimeter level.Distance on the surface of the material distance D is proportional to the pulse travel time T:

D=C×T/2

Where C is the speed of light

E known due to empty cans of distance, the level of L as follows:

L=E-D

The output

By entering empty cans height E (= zero), full tank height F (= full scale) and some applications to set parameters, application parameters will be automatically adapt instrument to measure the environment.Corresponding to the 4-20 ma output.

Applications:

ZWRD600 series pulse radar level gauge is suitable for liquid, paste, and granular material a non-contact continuous measurement, suitable for temperature, pressure change is big;The presence of inert gas and volatile situation.Using microwave pulse measurement method, and can be within the scope of industrial frequency band to work normally.Beam energy is low, can be installed in all kinds of metal, non-metallic vessel or pipe, no harm to human body and environment.

Four, the main features:

1, no blind area, high precision.

2, two wire system technology, it is the differential pressure instruments, magnetostriction, rf admittance, magnetic flap instrument of good alternatives.

3, is not subject to pressure, temperature changes, inert gas, vacuum, dust, steam and other environmental impacts.

4, installation is simple, durable and maintenance free.

5, HART and PROFIBUS - PA communication protocol and the foundation fieldbus, calibration is simple, through digital LCD easy calibration operation, through software GDPF simple configuration Settings and programming.

6, measurement sensitivity, fast refresh.

7, suitable for high temperature working condition, process temperature up to 200 ℃, when high temperature to extend the antenna is used up to 300 ℃.

Five, the technical parameters:

1, the working frequency: 6.8 GHz;

2, measuring range: cable type: 0-35 m pole type, coaxial type: 0-6 m;

3, repeatability, plus or minus 3 mm;

4, resolution: 1 mm;

5, sample: echo sampling/s 54 times;

6, the response speed: > 0.2 S (according to the specific use of the case may be);

7, precision: < 0.1%;

8, the output current signal: 4-20 ma;

9, communication interface: HART communication protocol;

10, process connection: G1-1/2, G3/4 flange: (, DN80, DN100, 6;

11, the process pressure: 1 ~ 60 bar;

12, power: 24 VDC ripple voltage (+ / - 10%) : 1 VPP;

13, power consumption: max22.5 mA;

14, environmental conditions: temperature: - 40 ℃ ~ + 250 ℃;

15, shell protection grade: IP68;

16, explosion-proof level: EXiaIICT6;

17, two wire connection: instrument power supply and signal output sharing two core cable;

18, cable entry: M20 x 1.5 (cable diameter 5 ~ 9 mm).

Six, installation guide:

The following installation instructions applicable to bar type probe and cable type, tubular type probe measurement has nothing to do with the installation.

1, the installation location:

A, distance of tank wall advice 1/6 - a quarter of the tank diameter (at least 300 mm, concrete tank at least 400 mm).

B, do not install in the middle of the metal cans;

C, don't put in the mouth;

D, when choosing the length of the probe, pay attention to the bottom of the probe from the tank bottom is about more than 30 mm;Pay attention to the medium temperature.

2, tank obstacles:

Pay attention to when installation probe at least 200 mm away from the obstacle.

3, remove interference:

, clutter echo suppression: a software which can realize the interference echo suppression, so as to achieve the ideal measurement effect;

B, the by-pass pipe and guided wave tube (only applicable to liquid) for viscosity don't play in the 500 CST, can adopt by-pass pipe, guided wave tube or pipe to avoid interference.

4, liquid standard installation:

For 500 CST or less and not easy to produce the adhesive medium viscosity, tubular probe is an ideal scheme, its characteristics are as follows:

A,, excellent reliability.

B, can be used in any medium, dielectric constant is greater than or equal to 1.4 measurement has nothing to do with the conductivity of medium;

C, tank obstacles and short tube size does not affect the measurement;

D, than bar type probe can withstand the lateral pressure is high;

E, for the high viscosity of the medium, it is recommended to use lever probe.

5, lie the tank and the installation of vertical tank:

A, tube type probe and bar type probe zui to 6 meters long for tank measuring distance of more than 6 m, can choose 8 mm cable type probe;

B, installed and fixed mode with solid powder storehouse measurement;

C, to the distance away from the tank wall unlimited, as long as avoiding probe contact tank wall;

D, if the tank obstacles more or too close to the ground rod, please choose tube type probe.

6, corrosive medium measurement:

If the corrosive medium, can choose lever probe measure set of a plastic casing.

Seven, measurement considerations:

1, measurement range from the beam hitting a can of low starting point, but under special circumstances, if the tank is low for concave type or conical, when the level below this point cannot be measured.

2, if the medium to low dielectric constant when it is in low level, low visibility, at this time in order to ensure the accuracy of measurement, the recommendations will be zero at low altitude to the position of the C.

3, theory, measurement to achieve the position of the antenna tip is possible, but considering the corrosion and the influence of the adhesive, the final value of measuring range should be at least 100 mm distance from the tip of the antenna.

4, the overflow protection, additional on the blind spot can define a safe distance.

5, measurement range related to the antenna.

6, with different concentration, foam can absorb microwaves, and it can be reflected, but under certain conditions can be measured.

7, measurement is beyond the scope of action when the measuring range beyond, instrument of 22 ma current output.

Eight, can debug through three ways:

1, by displaying the adjustment module PM;

2, through debugging software SOFT;

3, handheld programmer by HART.

Nine, through SOFT software debugging:

1, regardless of the signal output radar sensor can be through the software debugging.Is instrument with the SOFT software debugging, need a meter CONNECTCAT drives.

2, using the software debugging, give the radar instrument 24 VDC power, at the same time connect HART adapter front end with a resistance of 250 ohms.If the one-piece HART resistance (250 ohm internal resistance) of electricity meter, there is no need for additional external resistance, HART adapter can and 4...20 ma line in parallel.

Ten, use notice:

1, the meter used in outdoor, install the awning or protect box, lest time grew, LCD aging by sunlight.If used in the corrosive gas environment, need to install anti-corrosion coat, and outer casing and tighten the instrument into the outlet terminals.Where corrosive gas or liquid is used, or at the beach, sea use, need to choose anti-corrosion type.

2, wire, cable protection tube, pay attention to the seal to prevent water, to prevent rodent bite by rats, etc.

3, instrument, although itself with lightning protection device, instrument when used in dore region, Suggestions on the instrument into the outlet end of the other special installation of lightning protection devices.

4, instrument used in special hot and cold place, namely the ambient temperature may exceed the instrument work requirements, proposed around the liquid level meter high resistance, low temperature device.

5, radar and measured the level of vertical, the launch of the cone in radar electromagnetic wave must be within the scope of other obstacles.

6, if the < - 20 ℃ or > + 60 ℃ temperature for use, please in advance the company's technical service department.

7, using the environment with dust, vapor, mist, liquid level bubble, floats, liquid mixing, waves, and so on and so forth, please our company in advance technical service department, need to discriminate.

Eleven, parameter table:

Table 1:

Product category

ZWRD601

ZWRD602

ZWRD603

Product pictures

Six pulse radar level gauge 601 JPGSix pulse radar level gauge 602 JPGSix pulse radar level gauge 603. PNG

Range of application

Simple process conditions, corrosive liquid, paste, solid 
Such as: 
The water tank
Acid and alkali storage tank 
Slurry storage tank 
Solid particles
Small storage tanks

Storage container or process corrosive liquid, paste, solid 
Such as: 
The water tank
Acid and alkali storage tank 
Slurry storage tank 
Solid particles
Small storage tanks

To adapt to all kinds of storage container, liquid, paste, solid 
Such as: 
Crude oil, light oil tank
Raw coal, pulverized coal positions
Volatile liquid storage tanks
Coke material level 
Slurry storage tank 
Solid particles

measuring The amount van wai

20m

20m

30m

pass cheng evenPick up

G11/2or11/2NPTThe screw thread

The flange

The flange

pass cheng wenThe degree of

- 40-130℃

- 40-150℃

- 40-250℃

pass chengpressure force

-1.0-3bar

-1.0-20bar

-1.0-40bar

heavy after sex

± 3mm

± 3mm

± 3mm

fine The degree of

< 0.1%

< 0.1%

< 0.1%

frequency The rate of van wai

6.8GHz

6.8GHz

6.8GHz

explosion-proof/Protection grade

EXiaIICT6/IP68

EXiaIICT6/IP68

EXiaIICT6/IP68

The letter No.Lose, Out of the

The pulse signal output(The two lines)

The pulse signal output(Two lines)

The pulse signal output(The two lines)

Browse:
Return To The Top

分享到: