Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
0517-86918678
Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
Tel:0517-86918678
Fax:0517-86918679
Email:zhongweick@163.com
Post Encoding:211600
Instructions for Selection of Rotor Flowmeter with Metal Tube for Lithium Battery Power Supply
  • File Name:Instructions for Selection of Rotor Flowmeter with Metal Tube for Lithium Battery Power Supply
  • Add Time:2019-04-12 10:30:21
  • Document Size:
  • Recommendation:
  • Immediately Download:
Download Instructions:

Productoverview:
ZW-LZ series of lithium battery powered metal tube rotameter can realize the liquid crystal indicator, and cumulative output distance (4 ~ 20mA), pulse output, alarm output function, the intelligent signal transmitter and has high precision and reliability, and can completely replace the imported type instrument, and has high cost performance, multi parameter calibration, the power down protection etc..It is widely used in various industries complex, harsh environment, small volume and low velocity, a variety of harsh conditions of medium flow measurement and process control.
Two, the structure and principle of measurement:

1, structure:
ZW-LZ series of lithium battery powered metal tube rotameter is mainly composed of three parts:
A (Intelligent indicator, indicator, local indicator);
B, float;
C, a conical measuring chamber.
2, the principle of measurement:
On the lower end of the measured medium from the measuring tube through a conical float generating differential pressure form the upward force, when the float on the lift is greater than immersion float in the fluid weight, the float will rise, annulus area increases, the annulus fluid velocity decreased immediately, float on the lower pressure reduced, to float up with the decrease in stress, until the lift is equal to the weight of the float when immersed in a fluid, the float will stabilize at a certain height.The float position that corresponds to the size of the measured medium flow.A built-in magnet, the float with the medium moves up and down, with the movement of the float magnetic field changes.
A, for in situ, by rotary magnetic float and the local indicator in the inner magnetic coupling, rotate, and drives the pointer, through the dial indicates the size of the flow.
B, the intelligent, by a solid state magnetic sensor intelligent indicator in the magnetic field will change into electrical signal output by A/D transform, D/A microprocessor, LCD liquid crystal display to show the size and cumulative flow flow.
Third, widely used:
ZW-LZ series of lithium battery powered metal tube rotameter is reliable, low maintenance, long service life; widely used in chemical industry, power generation, food, water treatment etc..The complex and harsh environmental conditions, the flow measurement process and various medium conditions in.
Four, main features:
1, all metal structure design, strong, simple, high pressure resistance, high temperature resistance, corrosion resistance, long service life;
2, a short trip, the total height of 250mm, easy to install;
3, mechanical pointer instructions LCD liquid crystal display instantaneous flow, instantaneous flow, cumulative flow;
4, intelligent indicator, using the latest foreign signal processing chip, modular design, no hysteresis;
5, data recovery, data backup, power down protection and fault self diagnosis function;
6, HART type indicator, two-wire 24VDC power supply, 4-20mA standard current signal output of HART protocol stack;
7, through the HART communication manipulator configuration and parameters can be adjusted;
8, with the PC serial connection, through the Windows program, to achieve on-site calibration of the instrument;
9, can be used in flammable and explosive occasions;
10, vertical and horizontal, upper lower, bottom side, side into the side such as the installation of a variety of forms, flange or threaded connection.
Five, technical parameters:
1, water measuring range: 2.5 ~ 100000l/h (20 C)
2, range: 10:1
3, 1, 1.5, accuracy: 2.5
4, working pressure: DN15, DN25, DN50, PN4.0MPa, DN80, DN100 to 10.0MPa to PN1.6MPa to 6.4MPa
5, medium temperature: -40 to 300 DEG C
6, medium viscosity: DN15: <5mPa - s eta (F15.1 ~ F15.3)
<30mPa - S (F15.4 - F15.8)
DN25: <250mPa - s.
DN50: <300mPa - S - DN150.
7, the ambient temperature: LCD type: -40 to 85 DEG C
Pointer type: -40 to 120 DEG C
8, connection: flange (executive standard DIN2501 or as required by standard flange manufacturing)
9 meter height: 250mm
10, cable interface: M20*1.5
11, power supply: 24VDC two-wire 4 ~ 20mA or 85 ~ 265VAC 50/60Hz (remote type)
12, alarm output: alarm relay output lower or upper limit of instantaneous flow (contact capacity 5A-250VAC) or open collector output (maximum 100mA-30VDC internal impedance of 100 ohm).
13, the cumulative output pulse: pulse output, minimum interval of every 10 seconds a pulse (AC) or a pulse every 50 milliseconds.
14, double liquid crystal display: LCD display, display the instantaneous flow and cumulative flow.
15: Exia II CT4, explosion-proof.
16, the measuring tube material: 316 stainless steel (common type) or Teflon liner (corrosion type).
Six, product maintenance:
1, in the process of long-term use, the pipeline inevitably there will be ferromagnetic impurity adsorption on the float, it will float stuck or affect the measurement accuracy, from time to time to clean the sensor float; if the installation of magnetic filters should be cleaned regularly.
2, instrument indicator equipped with electronic components, instrument wiring or demolition of housing, to housing screws, must ensure sealing, prevent impurities, or other material into the water, and also to ensure reliable earthing of the meter casing.
3, instrument installation, on first use, should pay attention to:
When the valve is opened to avoid the formation of pressure shock makes the float slamming limiting device, causing damage to the instrument, slowly open the valve!
The measurement of gas meter is equipped with gas damper, to minimize the shock; to ensure the stability of the float, a throttle valve can be installed in the instrument export.
4, for the remote type instrument, we must first ensure that the instrument wiring correctly, keeps power; for dangerous situations, must choose the explosion-proof, and the installation and use of proof required by the.
Seven, structure classification:
1, the high temperature structure (G type)
High temperature structure type (G type) is used for medium temperature is too high or too low and the need to take measures on the insulation of the measuring tube medium flow measurement.The high temperature structure is increased and the distance between the measuring tube indicator to increase heat dissipation and increase the insulation thickness, ensure the working environment temperature indicator in the allowable range.The selection of the "G" type.
The flow of G type metal tube flowmeter can measure the temperature of -80 DEG -+300 DEG medium.
The structure of 2, with a damper device (Z type)
Damper structure type flowmeter for entrance flow (pressure) medium flow measurement is unstable, especially for gas measurement.
3, jacket type structure (T type)
Jacket structure for heating or cooling of needs (such as high viscosity and flow measurement of the medium Yi Jiejing).In the jacket by heating or cooling medium, fluid vaporization and no crystallization.
Import and export with thermal medium connection standard to use HG20594-97 DN15 PN1.6 flange, flange connection and other specifications may be marked with production plant, pressure rating jacket for 1.6MPa.
Jacket type flowmeter structure see FA standard flange type flowmeter and the size of map.
4, high pressure type structure (Y type)
High pressure type structure for media pressure is greater than the standard pressure level measurement.At present, the maximum pressure can reach 32MPa.In addition high pressure type flowmeter can provide built-in magnetic filter type, installation height is 350mm.FA, FB and FC type maximum pressure of 10MPa.
Troubleshooting eight fault:
1, check the alarm set value size SU.
2, check the deviation set D value can not be too large.
3, FUN function, logic function is correct.HA-A said the upper limit is logical.LA-A said the lower limit is.
4, circuit board failure, replace the board.
5, if the lcd barcode indicates the correct output, no action, the cathode can check the external power and external power supply is connected with the anode of instrument power supply.
If the wobble in use, according to the jitter amplitude to determine what kind of amplitude jitter.Divided into mild and moderate jitter jitter jitter and jitter.
1, a slight jitter due to fluctuations caused by the media.Can be used to increase the damping of the way to overcome.
2, moderate jitter caused by medium flow state: general.For general gas as the medium pressure instability caused by.The regulator or stabilizer to overcome or increase the damping of gas meter.
3, severe jitter: mainly due to medium gas pulsation, operation pressure instability or give users pressure, temperature, flow meter and the actual state does not have large differences over range instrument.
Nine, installation requirements.
Remove the filler, 1 meter box after check, the meter should be installed vertically in the pipeline without vibration, such as to the level of the installation, the order should be additional instructions.The angle between the line and the plumb line flowmeter center should not exceed 5 degrees.
In 2, the newly installed pipeline flow meter should be installed before the new pipeline clean metal pipe, if the measured medium containing impurity particles or bubbles, you should install filtering device or exhaust in flowmeter installation, the fluid must be flowing from down to up, if the fluid flow from top to bottom, then the flowmeter can not work.If the measured medium is pulsating flow, it should be appropriate to the size of the buffer device is arranged in the downstream, such as surge tank to eliminate pulsation.
3, in order to check the meter zero and disassembly and maintenance and debugging, should stop valve and bypass valve installed in the upstream and downstream flow meter.
4, an instrument according to the provisions after installation, should close the flow meter on the downstream shut-off valve, check again with the two meter instrument wiring, error free, open the two meter power supply is the instantaneous flow rate should be zero.For normal use, you should first open the upstream valve is fully open, with a metal tube flowmeter downstream from the valve slowly adjust the flow, instantaneous flow should change.Stop working when they should close the valve, then close the upstream downstream of the valve.

Table ten parameters:

Path

(mm)

Flow range

The pressure loss of KPa

Water L/h

Air m3/h

water

atmosphere

The conventional type

Anti-corrosion type

The conventional type / anti-corrosion type

The conventional type

Anti-corrosion type

Fifteen

2.5-25
4.0-40
6.3-63
10-100
16-160
25-250
40-400
63-630

2.5-25
4.0-40
6.3-63
10-100
16-160
25-250
40-400

0.07-0.7
0.11-1.1
0.18-1.8
0.28-2.8
0.48-4.8
0.7-7.0
1.0-10.0
1.6-16.0

Six point five
Six point five
Six point six
Six point six
Six point eight
Seven
Eight point six
Eleven point one

Five point five
Five point five
Five point six
Five point six
Five point eight
Six point one
Seven point three

Seven point one
Seven point two
Seven point three
Seven point five
Eight
Ten point eight
Ten
Fourteen

Twenty-five

100-1000
160-1600
250-2500
400-4000

63-630
100-1000
160-1600
250-2500

3-30
4.5-45
7-70
11-110

Seven
Eight
Ten point eight
Fifteen point eight

Five point nine
Six
Six point eight
Nine point two

Seven point seven
Eight point eight
Twelve
Nineteen

Fifty

630-6300
1000-10000
1600-16000

400-4000
630-6300
000-10000

18-180
25-250
40-400

Eight point one
Eleven
Seventeen

Six point eight
Nine point four
Fourteen point five

Eight point six
Ten point four
Fifteen point five

Eighty

2500-25000
4000-40000

1600-16000
2500-25000

60-600
80-800

Eight point one
Nine point five

Six point nine
Eight

Twelve point nine
Eighteen point five

One hundred

6300-63000

4000-40000

100-1000

Fifteen

Eight point five

Nineteen point two

One hundred and fifty

20000-100000


600-3000

Nineteen point two


Twenty point three

11, selection table:

ZW-LZ

Description (Zhongwei control)


Code

indicator

Z

Basic type indicator

D

The remote type indicator


Code

Nominal diameter

-15

DN15

-25

DN25

-40

DN40

-50

DN50

-80

DN80

-100

DN100

-150

DN150


Code

structural style

/

In the next

H1

The left into the right

H2

Right into the left out

AA

The side into the side

LA

The bottom side

S

Threaded connection

M

Quick coupler


Code

Body material

R1

321 stainless steel

R4

304 stainless steel

R6

316 stainless steel

R6L

316L stainless steel

Hc4

Ha C alloy

Ti

titanium

F

With F46 (PTFE)


Code

Type indicator

M7

Linear indicator

M9

Nonlinear indicator (local pointer display flow)


Code

Combination function

ESK

24VDC; remote 4-20mA standard current signal

ESK-Z

24VDC; remote 4-20mA; LCD display instantaneous and cumulative flow field

ESK-D

The power lithium battery; LCD display instantaneous and cumulative flow

K1

With an on-line alarm signal

K2

With on-line alarm signal

K12

With a line and a line alarm signal


Code

Explosion proof type

Ex

Explosion-proof

Exd

Flameproof


Code

Measuring medium classification

L

liquid

G

Gas


Code

Increase function

T

The measuring tube with a heat / heat insulation jacket

HT

More than 120 degrees high temperature medium temperature measurement


Browse:
Return To The Top

分享到: