Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.

Electrically traceable magnetic tilting plate level gauge

17电伴热型磁翻板液位计01.jpg
  • 17电伴热型磁翻板液位计01.jpg
Electric heat tracing type magnetic tumbler level gauge is a product that imports and absorbs simila…

Description:

Productoverview:

ZW-UHZ-51R series <strong> of electric heating type magnetic level gauge</strong> is suitable for industrial production in the process of pressure (or open) liquid storage equipment (tower, cylinder, tank, spherical container and boiler) of the liquid level detection. Can display the work and all kinds of liquid level height.

The position signal transmitter can teleport with level, achieve the automatic control and measurement of liquid level by certain electrical installations. Meter level meter is a reliable safety. Because of the isolation of magnetic coupling sealed structure, especially suitable for the liquid level detection of flammable and explosive and corrosive toxic liquid, simple and safe and reliable so that the liquid level detection means the original complex environment change.

Liquid level meter has the characteristics of direct reading display, does not need to set level meter, can monomer for the whole range of measurement. The equipment has less holes, clear display, eye-catching signs, visual reading etc..When the liquid level meter with direct display instrument can save the intermediate transmission signal detection system to improve the transmission accuracy.

Two, work principle:

1, the basic type

ZW-UHZ-51R series <strong> of electric heating type magnetic level gauge</strong> according to the principle of buoyancy, the float with the liquid level measuring tube at the lifting up and down inside the float magnet by magnetic coupling effect, driving the red and white flip turn column 180 'level rises, turn column turned from white to red, down, turn column from red to white, so as to achieve the level of instruction.

2, limit switch output

The use of magnetic float with the liquid level gauge is installed in the mobile, the vertical tube set position switch, realize on-off control or alarm.

3, the electric remote

The magnetic level gauge transmitter installation. The sensor and transmitter converter is composed of two parts, the magnetic float moves up and down by the magnetic coupling of the measuring element in intraductal action, obtain the resistance signal changes, summoned into 0~10 or 4 ~ 20mA standard current signal output, and digital display connected to the instrument or computer, realize remote display and control.

Three, application:

ZW-UHZ-51R series <strong> of electric heating type magnetic level gauge</strong> on the container according to the installation position, side loading and top loading modes. According to the different media, provide two kinds of engineering plastics and ABS stainless steel material; the ABS is especially suitable for acid, alkali and other corrosive medium. Widely used for liquid level measurement and control of electric power, petroleum, chemical, metallurgy, shipbuilding, construction, environmental protection, food and other industries in the production process.

Four, main features:

1, suitable for measurement of liquid level, interface liquid medium container. In addition to the instructions, can be equipped with remote transmitter, alarm switch, detection function.

2, indicating novel, intuitive readings, eye-catching, observe the direction of the indicator according to user needs to change the angle.

3, measurement, not affected by tank height restrictions.

4, indicating mechanism and the measured medium is completely isolated, good sealing performance, high reliability, safe use.

5, simple structure, convenient installation, convenient maintenance, corrosion resistance, no power, explosion-proof.

Five, technical parameters:

1, the range (mm): 300~81000;

2, medium density (g/cm3): 0.5 ~ 2;

3, medium viscosity: less than 0.02Pa.S;

4, working temperature: -40 ~ 350;

5, pressure level (MPa): less than 32;

6, the measurement accuracy (mm): less than 10;

7, installation: side mounted, top mounted, bottom mounted;

8, protection grade: IP65;

9, explosion-proof grade: IB II CT4 (Ben Anxing), D II (BT4 flameproof);

10 transmission modes: 4 ~ 20mA or switch;

11: PN4.0 DN25 HG20593, the interface flange (side mounted) PN1.0 DN100 HG20593 (top mounted, bottom mounted), can be customized according to the needs of users. Note: when installed under the influence of environment security level gauge, the space position of L1<300 order should be significantly raised.

Six, additional option:

Limit switch:

Open type: alarm with higher than

Normally closed type: higher than the alarm off

Switch capacity: 250VAC1A (resistive) 250VAC0.3A

Switch life: 100000 times

Liquid level transmitter:

Output current: 4-20mADC

Resolution: + 1- + 10mm

Load resistance: 500 ohms (24VDC power supply)

Transmission distance: 3000m

Power supply: 16-30VDC

Intelligent liquid level transmitter:

Output current: 4-20ADC

Resolution: 0.2mm

Load resistance: 500 ohms (24VDC power supply)

Transmission distance: 3000m

Power supply: 16-30VDC

Seven, classification and application:

1, ordinary type: suitable for low, medium and high pressure, no special requirement for anticorrosion occasions.

2, vacuum type: suitable for ultra low and high temperature, high pressure, low, and no special requirement for anticorrosion occasions.

3, frost proof: suitable for low temperature and low pressure, and no special requirement for anticorrosion occasions.

4, type: suitable for underground buried or openings at the top of the tank, the medium movement is not the occasion.

5, jacket type: suitable for thermal insulation or cooling, low, medium and high pressure, no special requirement for anticorrosion occasions.

6, the lining or other type: PTFE lining, suitable for special anti-corrosion requirements of the low, middle and high pressure situations.

7, anti-corrosion type: PP or PVC material, suitable for normal temperature and atmospheric corrosion resistant occasions.

Eight, installation, use and maintenance:

1, level gauge must be installed vertically, to ensure that the magnetic float movement in the main duct freely up and down.

A stop valve is arranged between the 2, the liquid level meter and the container, so that cleaning and maintenance to cut materials.

3, level gauge cylinder around a magnet close to not allow, otherwise it will directly affect the level of normal work.

4, level meter factory general insulation, but according to user needs for insulation, such as the user uses the hot mix line, must use the non-magnetic material.

5, to prevent the magnetic float transport at the leading high speed sliding tube to be hit, level meter factory, with Cathy will be fixed on the lower magnetic float liquid guide pipe, the user should be removed card silk can be installed prior to installation and use.

6, level meter installed, with magnetic correction of magnetic guidance once to zero below zero above the red, white

7, level gauge is put into operation, should open the valve on the liquid guide pipe, then slowly open under the liquid guide pipe valve, let the liquid medium smoothly into the main canal, avoid the liquid medium with a rapid rise caused by magnetic reversal failure or disturbed (in case of this phenomenon, the magnet available for calibration.)

8, open the bottom flange plate is installed in the magnetic float boring, heavy, should pay attention to end with a magnetic end up not flip.

9, level gauge cylinder should be solid impurities and magnetic impurities, so as to avoid jamming and weaken the buoyancy of the float.

10, according to the media, the leading tube can be cleaned regularly, remove sediment impurities in pipe.

Nine, the installation process:

1, after the factory, has assembled all the debugging, arrived at the scene, the first step must first clean up *, the need to install the equipment.

2, ready to install the necessary tools and bolts and manufacturers and distribution of the turning column indicates the calibration bar.

3, wipe scene flange, adjust equipment flange and magnetic level gauge flange on the straight, must keep the magnetic level gauge body vertical, and then put into the 4 hole bolt flange tool.

Ten, installation notes:

1, level gauge must be installed vertically, to ensure that the floating ball components in the main tube moving up and down freely.

2, level gauge around the main body does not allow the magnetizer near or directly affect level meter to work correctly.

3, level meter installed, need to use steel to correct a double bead guide to make zero position below zero above the display shows a red, white.

4, level meter running should first open the liquid guide pipe valve for liquid medium smoothly into the main pipe, avoid liquid medium with floating ball components caused by the rapid rise, turn turn bead failure and shuffle. If this occurs to the surface smooth available after re correction magnet.

5, due to the transport process in order not to float the component damage, before the factory will float out of the main pipe component level meter, liquid meter after installation, open the bottom discharge flange, then float assembly back in the main tube, pay attention to a heavy floating ball assembly on the head, not flip.

6, according to the media, can regularly open the sewage main pipe flange cleaning sediment.

Eleven, selection and installation:

1, we must first understand the equipment running their own situation, what is the measuring medium, even if they do not need to know what material, our company also can determine the material according to the medium used equipment.

2, when equipped with the remote meter to do the following, should make the remote meter to gauge leading tube, stainless steel hoop is fixed (disable iron); the remote meter should be on the surface should be oriented and close to the main duct; the remote meter should be zero and gauge zero instructions in the same horizontal line; remote meter and display instrument or computer connection alone wear protective pipe laying or shielding two core cable connection box; a wire inlet hole after laying, requires good sealing, in order to avoid rain, moisture intrusion and make remote matching instrument can not work normally, the junction box in the repair or completion of commissioning should be timely cover.

3, according to the media, cleaning the main duct to remove impurities;

4, for more than a certain length (common type > 3 meters, 2 meters, anti-corrosion type) of the liquid level meter, need to increase the middle reinforcement flange or lug fixed support, to increase the strength and overcome their weight;

5, magnetic position, board level meter should be avoided or away from materials import and export department, to avoid the rapid change of fluid material in local area, affecting the accuracy of liquid level measurement;

6, when debugging, should open the upper guide pipe valve, and then slowly open the valve at the lower part, so that medium smooth entry duct (to avoid the rush of media should be run in the float float, cause drama column fluctuation, affecting the display accuracy), observe the red ball magnetic flip is normal, and then close the lead pipe valve, open the drain valve so, the main duct level drops, according to the method, the operation three times, it is normal, can be put into operation (except special corrosive liquid); magnetic level gauge in the market there are other names, also called magnetic level gauge, or magnetic level gauge, also called magnetic float liquid level gauge. But they need to know the order parameter is certain, such as corrosive medium needs anticorrosive material, corrosion corrosion grade equivalent grade according to the changes of the medium. For example, the special situation of their own equipment, determine the installation mode of the magnetic level gauge, because some places do not fit or do not apply some installation methods.

Twelve, the selection of encoding:

ZW-UHZ-

A series of magnetic level gauge (Zhongwei control)

 

Basic types

Fifty-one

Magnetic indicator


Fifty-two

Magnetic indicator - Remote output


A

Basic type ( Side mounted )

B

Insulation type (jacket) S Frost proof R Electric heating type

C

Insert type (top mounted)

D

Corrosion proof type (side mounted anti-corrosion type)

E

Insert (top mounted type heat insulation type)

F

Insert the anti-corrosion type (top mounted anti-corrosion type)

G

Heat resistant type


One

No alarm

Two

belt One Only the alarm point

Three

belt Two Only the alarm point

Four

belt Three Only the alarm point

Five

belt Four Only the alarm point


Five

Stainless steel

 

The main materials

Six

Corrosion protection of aluminum

Seven

titanium

Eight

PVC

Nine

PTFE package


A

-40-0 C

 

working temperature

B

Less than or equal to 80 C

C

Less than or equal to 100 C

D

Less than or equal to 150 C

E

Less than or equal to 300 C

F

Less than or equal to 350 C

G

Less than or equal to 480 C


A

0.6 Mpa


 

The actual pressure

B

1 Mpa


C

1.6 Mpa


D

2.5 Mpa


E

4.0 Mpa


F

6.3 Mpa


G

10 Mpa


H

16 Mpa


I

22 Mpa


J

32 Mpa




L

The proportion of medium (g/ M)

L

Length measurement

L

The connecting flange ( DN )

L

output signal 4-20mA

Thirteen, please provide the following data:

1, specifications; magnetic level gauge: ZW-UHZ series;

2, the measured medium Name: medium density: if you do not know the density, can tell us the name of the medium, which is composed of mixed liquid to know several liquid;

3, the instrument measuring range: also known as nominal length, which is a flange of the center distance, or look at the scale of products already in use;

4, working pressure: pressure;

5, working temperature: measure the temperature of the liquid;

6, material requirements: wetted materials, such as do not know what kind of material, can give us advice (general liquid is what material we can use what material);

7, supporting the supply of flanges, bolts and nuts, valve, sealing washers and other accessories;

8, standard: flange flange nominal diameter, the most used flange is DN20 or DN25;

9, special requirements: please indicate in detail before ordering, such as whether or not to take the remote, insulation jacket etc..

Customer service service commitment?:

1, our level meter series products quality problems within twelve months, responsible for free maintenance.

2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.

3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.

4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.

5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.


Browse:
Return To The Top

分享到: