Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
0517-86918678
Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
Tel:0517-86918678
Fax:0517-86918679
Email:zhongweick@163.com
Post Encoding:211600

Compensation conductor

补偿导线.jpg
  • 补偿导线.jpg
Compensation conductor should be divided into extension type and compensation type two kinds, fluori…

Description:

An overview, cables:
Compensation wires and compensation cables, to a certain temperature range (including temperature) with the matched the thermocouple thermoelectric emfs values the same couple or more with insulated wire or cable, use them to connect the thermocouple and measuring devices, to compensate them with the error produced by the temperature change of the thermocouple junction, compensation wires and compensation cables are divided into extension type and compensation type two kinds, fluorine plastic wire or cable and silicon rubber insulation resistance to high temperature compensation is more high temperature resistant, cold resistant, resistant to acid and alkali oil and water, don't delay burning, anti-aging and other advantages, the products are widely used in petroleum, chemical industry, electric power, metallurgy, medicine, textile and other factories and scientific research departments in the temperature measurement and control system.
Second, the compensating conductor standards:
GB/T4989-94 (equivalent to the IEC584-3 standard)
Three, compensation conductor used features:
1, the highest working temperature conductor: 70 ℃ polyvinyl chloride (PVC) 200 ℃ and 180 ℃ 105 ℃ silicone rubber fluorine plastic meltability polytetrafluoroethylene (PTFE) 260 ℃
2, the lowest temperature:
PVC sheathed: fixed installation to 40 ℃, the fixed installation to 15 ℃.Fluorine plastic and silicone rubber sheath: fixed installation - 60 ℃, the fixed installation - 20 ℃.
3, cable allows bending radius: the minimum armored cable is 6 times of overall diameter;Copper tape screened or steel tape armoured cable minimum 12 times of cable diameter;Fluorine plastic insulation and sheath minimum 10 times of cable diameter.
Four, compensation conductor should be the basic model and name:

model

Products name said

KX-GS-VV

PVC insulated PVC sheathed general in dividing precision grade K thermocouple compensating cable

KX-GS-VVP

PVC insulated PVC sheathed wire braided total screen precision grade K is commonly used in dividing thermocouple compensating cable

KX-GS-VPV

PVC insulated PVC sheathed wire woven on screen in general by the level of precision indexing number K thermocouple with compensation cables

KX-GS-VPVP

PVC insulated PVC sheathed wire woven on total screen is usually in dividing precision grade K thermocouple with compensation cables

KX-HS-FF

Fluorine plastic insulation and sheath heat by the level of precision index number K thermocouple with compensation cables

KX-HS-FFP

Fluorine plastic insulated and sheathed wire braided total screen heat by the level of precision indexing number K thermocouple with compensation cables

KX-HS-FPF

Fluorine plastic insulated and sheathed wire weaving on screen heat by the level of precision indexing number K thermocouple compensating cable

KX-HS-FPFP

Fluorine plastic insulated and sheathed wire weaving on total screen heat in dividing precision grade K thermocouple compensating cable

KX-HS-FG

Fluorine plastic insulation silicone rubber sheath heat by the level of precision index number K thermocouple with compensation cables

KX-HS-FGP

Fluorine plastic insulation silicone rubber sheath copper wire braided total screen heat in dividing precision grade K thermocouple compensating cable

KX-HS-FPG

Fluorine plastic insulation silicone rubber sheath copper wire woven on screen heat by the level of precision indexing number K thermocouple compensating cable

KX-HS-FPGP

Fluorine plastic insulation silicone rubber sheath copper wire woven on total screen heat in dividing precision grade K thermocouple compensating cable

KX-HS-FV

Fluorine plastic insulated PVC sheathed heat by the level of precision index number K thermocouple with compensation cables

KX-HS-FVP

Fluorine plastic insulated PVC sheathed wire braided total screen heat by the level of precision indexing number K thermocouple with compensation cables

KX-HS-FPV

Fluorine plastic insulated PVC sheathed wire woven on screen heat by the level of precision indexing number K thermocouple compensating cable

KX-HS-FPVP

Fluorine plastic insulated PVC sheathed wire woven on total screen heat in dividing precision grade K thermocouple compensating cable

KX-HS-GG

Silicone rubber insulated and sheathed heat by the level of precision index number K thermocouple with compensation cables

KX-HS-GGP

Silicone rubber insulated and sheathed wire weaving total screen heat in dividing precision grade K thermocouple compensating cable

KX-HS-GPG

Silicone rubber insulated and sheathed wire weaving on screen heat by the level of precision indexing number K thermocouple compensating cable

KX-HS-GPGP

Silicone rubber insulated and sheathed wire weaving on total screen heat in dividing precision grade K thermocouple compensating cable

Note: 1, the above models only list the KX, other such as SC, KC, EX, BC, TX, JX need to change the first model;
2, before this Ann model compensating cable type charging "ia";
3, flame retardant, compensation cable type filling before "out";If you need armoured can refill "22" after the model;If you want to block, can indicate shielding in style: P, P1 tin plated copper wire, copper wire P2 copper strip, P3 lu: su composite film;Conductor for multiple strands of soft core, should inject "R" after the model.
4, PTFE ZR190 for imported materials, heat-resistant 260 ℃.
Five, compensation conductor should be the main technical indicators:

Compensation conductor model

With thermocouple

Thermocouple index number

Compensating lead wire

Insulating layer coloring

The anode

The cathode

The anode

The cathode

SC

10 - platinum platinum rhodium thermocouple

S

SPC (copper)

SNC (copper, nickel)

red

green

RC

13 - platinum rhodium platinum thermocouple

R

RPC (copper)

The RNC (copper, nickel)

red

green

KCA

Nickel chrome - nickel silicon thermocouple

K

KPCA (iron)

KNCA (copper, nickel)

red

blue

KCB

Kleiner perkins caufield & byers (copper)

KNCB (copper, nickel)

red

blue

KX

KPX (nickel chrome)

KNX (nickel silicon)

red

black

NC

Nickel chromium silicon - nickel silicon thermocouple

N

NPC (iron)

NNC (copper, nickel)

red

grey

NX

NPX (nickel chromium silicon)

NNX (nickel silicon)

red

grey

EX

Copper nickel chrome - nickel thermocouple

E

EPX (nickel chrome)

ENX (copper, nickel)

red

brown

JX

Iron, copper and nickel thermocouple

J

JPX (iron)

JNX (copper, nickel)

red

The purple

TX

Copper, copper nickel thermocouple

T

TPX (copper)

TNX (copper, nickel)

red

white

Note: type the first letter and the thermocouple corresponding to the index, the second letter in "C" said compensation conductor, the letter "X" said compensation conductor should be extended type.SC type can be compensation conductor with R type degree thermocouple.