Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.

Double flange level transmitter

24双插法兰式液位变送器.jpg
  • 24双插法兰式液位变送器.jpg
Double flange level transmitter is the introduction of foreign advanced technology and equipment in …

Description:

Products overview:

ZW3051LTS seriesDouble flange level transmitterIs a remote transmission device on a pipe or container to feel the pressure, the pressure inside by capillary pump silicone oil (or other liquid) to the body of the transmitter, then the transmitter inside the body and amplification circuit board, converting pressure or differential pressure into 4-20 ma.Dc signal output.Far eastone pressure, differential pressure transmitter and combination of intelligence amplification board, can constitute a smart remote transmission pressure, differential pressure transmitter, and conform to the HART protocol with the hand of the operator, can communicate, to set up and monitor.In order to adapt to different installation requirements, this series transmitter has many forms of remote transmission device for the user to choose from, main body structure and differential pressure transmitter, the pressure transmitter is the same.

Can accurately measure differential pressure, and converts it into DC4 ~ 20 ma output signal.The transducer adopted by micro processing technology made of silicon micro capacitive sensor and microprocessor, has excellent features and functions, small, lightweight, good environmental adaptability, applicable to all areas.If use handheld communication device (sold separately), through remote operations, in does not affect the transmitter DC4 ~ 20 ma output signal at the same time, for display and setting.

Second, the working principle:

ZW3051LTS series double plug flange level transmitter measuring principle is when two of the measured medium pressure ventilation with high and low pressure chamber, two role in the delta components (i.e., sensitive element) on both sides of the isolation diaphragm, through spacer and components on both sides of the filling liquid to measure the diaphragm.Liquid level transmitter is by measuring diaphragm and on both sides of the insulation on the electrodes of a capacitor.When we have different pressure on both sides, to cause measuring diaphragm displacement, the displacement and stress is directly proportional to the difference, so both sides capacitance range, through the link of oscillation and demodulation, is converted into is proportional to the pressure signal.

JiYiDuan allowed pressure liquid, the other end songs in phase, according to the principle of hydrostatics, are:

PB = PA + H rho g (2-1)

Type: H - liquid height;

Rho - density measured medium;

G - measured the local acceleration of gravity.

By type (2-1) available:

Δ P = PB - PA = H rho g

In general, the density of the measured medium and the acceleration of gravity is known, as a result, the differential pressure gauge measured the differential is proportional to the liquid height H, thus the measurement of the altitude of the liquid into the measurement of differential pressure problems.

Applications:

Insert ZW3051LTS series double flange level transmitter can avoid directly measured medium and transmitter isolation membrane contact, this method is applicable to the following several ways:

1, the sensitive element of transmitter measured medium corrosion were role;

2, need to be measured medium and high temperature transmitter isolation;

3, the measured medium has suspended solids or high viscosity medium;

4, the medium to be tested by the lead pipe at the same time easy to curing or crystal;

5, change must strictly to purify the measuring head measured medium;

6, measuring head must keep health, it is forbidden to pollution.Using the object: corrosive or viscous liquid.

Note: vacuum circumstance unfavorable use remote transmitter.

Four, the main features:

1, the super performance measurement for pressure, differential pressure, liquid level, flow measurement;

2, digital precision: + (-) 0.05%;

3, the simulation precision: + + (-) (-) 0.75% 0.1% F.S;

4, the whole performance: + 0.25 F.S (-);

5, stability: 0.25% 60 months;

6, span ratio: 100:1;

7, volume rate: 0.2 S;

8, miniaturization (2.4 kg) stainless steel flange, easy to install;

9, process connection compatible with other products, the realization of ideal measurement;

10, with H alloy sheath of sensors (technology), and achieved excellent cold and hot stability;

11, using 16 computer intelligent transmitter;

12, standard 4-20 ma, with digital signal based on HART protocol, remote control;

13, support to the field bus and upgrade based on the technology of field control;

Five, the technical parameters:

Output signals: 4 ~ 20 ma DC two wire (simulated)

Two wire 4 ~ 20 ma digital signal superimposed on the dc signal, the linear output or prescribing selected by the user.(smart);

Power supply: 12 ~ 45 v DC;

Power supply: < 0.005% output range/V;

14, to avoid directly measured medium in transmitter isolation diaphragm contact provides a reliable measuring method;

Resistance, : usually can be adjustable between 0.1 ~ 16 seconds, when the pump inert liquid or remote transmission device, the time constant will increase;

Start time: < 2 seconds, without preheating;

Working environment: the environment temperature - 29 ~ 93 ℃ (analog amplifier);

- 29 ~ 75 ℃ (digital/intelligent amplifier);

- 29 ~ 65 ℃ (with display meter);

Environmental humidity 0 ~ 95%;

Protective features: protection IP65;

Explosion-proof type, flameproof Exd II BT4-6;

The Ann model Exia CT5 II;

Static effects: zero error: plus or minus 0.5% z limit value in a wide range, for 32 mpa in the pipes under pressure by zero correction;

Electromagnetic radiation effects: 0.05% z value in a wide range, accept radiation frequency 27 ~ 500 MHZ, experimental field 3 v/m;

Indicator (%) : LCD digital display precision of + / - 0.2%;

200 hz vibration impact: any direction vibration, plus or minus 0.05% / g;

Installation location: diaphragm is not installed vertically, the zero error of less than 0.24 KPa may be produced, but can be modified by zero;

Weight: 3.9 Kg (not including attachments).

Six, with remote transmission device of liquid level transmitter is applicable to the following conditions:

1, you need to high temperature medium from the transmitter.

2, corrosion transmitter sensitive element for measuring medium.

3, due to environment or measured medium temperature change and solidifying or crystallization.

4, replace the measured medium need strictly to purify the measuring head.

5, suspending liquid or high viscosity medium.

6, measuring head must maintain clean sanitation.

7, sealing pressure container.

Seven, matters needing attention and routine maintenance:

1, using a new double flange differential pressure transmitter, to check the flange in the diaphragm liquid adequacy (how many of each production electrode internal charging different requirements), such as too little, should be returned to the factory maintenance.

2, for never immersed in solution of diaphragm and dry on the sensor for a long time, before use to need to look at is damaged, the purpose is to make after compression, sensor diaphragm rupture, causing the oil mixed with measuring medium.

3, daily use flange removal should be used when not in use cases, avoid by all means will be diaphragm bare outside.

4, need not can do put for a long time, often use zui good save in the fluid of the electrode to protect, but to soak activated before use.

5, measurement of acid alkali will greatly reduce the electrode life, so if you need frequent measurement of acid alkali zui good special acid alkali resistant diaphragm of choose and buy.

6, membrane cleaning water, water should not be too big, do not use scrubbing brush iron or other metal.

7, flange to should take put down gently, the diaphragm is very fragile, so as not to knock against.

Eight, selection considerations:

1, the model selection according to specification table according to the need to make sure.

2, selection of specifications in the table Numbers, symbols must be fill in clear, accurate.

3, if you have positive and negative migration, must indicate the migration amount value.

4, differential pressure transmitter to match three valve group, need to be indicated separately.

5, when far eastone transmitter of choose and buy, should also be based on different remote flange selection table according to the need to be sure.

6, if the remote transmitter should be used in vacuum and high temperature occasion, special label when you order.

7, contact medium type O sealing ring material is rubber, fluorine rubber, etc.

8, no special note, the factory when the liquid silicone oil.

Nine,Selection of code:

ZW3051LTS

Double flange level transmitter (work pressure2.5MPaWei measurement in) (the)

code

Scale range

3

0-1.3~7.5KPa

4

0-4-40KPa

5

0 to 40~200KPa

6

0-0.16KPa~1MPa

code

The output

E

4-20mA

S

Intelligent typeHARTagreement

code

Nominal diameter sizemm

Insert tube lengthmm

High side diaphragm material

A0

3"80

flat

316LSST

A2

3"80

50

316LSST

A4

3"80

100

316LSST

A6

3"80

150

316LSST

B0

4"100

flat

316LSST

B2

4"100

50

316LSST

B4

4"100

100

316LSST

B6

4"100

150

316LSST

C0

3"80

flat

hartzC-276

C2

3"80

50

hartzC-276

C4

3"80

100

hartzC-276

C6

3"80

150

hartzC-276

D0

4"100

flat

hartzC-276

D2

4"100

50

hartzC-276

D4

4"100

100

hartzC-276

D6

4"100

150

hartzC-276

E0

3"80

flat

tantalum

F0

4"100

flat

tantalum

code

Installation of flange

A

3"150lb

B

4"150lb

C

3"300lb

D

4"300lb

code

" constitutive material material

Flange and joint

exhaust/The drain valve

Isolation diaphragm

Pump the liquid

22

316Stainless steel

316Stainless steel

316Stainless steel

Silicone oil

23

316Stainless steel

316Stainless steel

Hartz alloyC

24

316Stainless steel

316Stainless steel

monel

25

316Stainless steel

316Stainless steel

tantalum

33

Hartz alloyC

Hartz alloyC

Hartz alloyC

35

Hartz alloyC

Hartz alloyC

tantalum

code

options

M1

0-100%Linear indicator

M3

3One and a halfLCDAccording to the table

M4

Intelligent table shows

B1

Bend tubes of stents

B2

Plate bending bracket

B3

Pipe bracket with flat

D1

The upper side discharge valve in the pressure chamber

D2

Lateral release valve at the bottom of the pressure chamber

Don't note

1/2NPTTaper pipe nipple

C2

Jump nippleM20×1.5After,

The weldingФ 14 System pressure tube ball cone head

d

flameproofdⅡBT4

i

The Ann modeliaⅡCT6

Ten, design selection and ordering information: 

1, working pressure also depends on the selection of the specifications of the flange.

2, remote transmission device working temperature, the choice of types of liquid filling.

3, far eastone pressure transmitter is one side of the remote device by temperature effect, the output generated by the change.

4, static pressure and temperature, were measured in the maximum range.

5, far eastone pressure transmitter on one side of the capillary length is 1.5 meters, commonly length shoulds not be more than 3 m agreement to special cases.

After-sales service commitment:

1, our company sold by liquid level transmitter series products within twelve months appear quality problem, is responsible for free maintenance.

2, the warranty period, any quality problems such as the products of our company, my company is responsible for free repair or replacement.

3, the warranty period, such as user improper use, damaged products, my company is responsible for the maintenance, charge damage parts cost.