Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.

Intelligent electromagnetic heat meter

32电磁热量表(智能).jpg
  • 32电磁热量表(智能).jpg
ZW - LDR seriesIntelligent electromagnetic heat meterIs a kind of measuring heat transformation in t…

Description:

Products overview:

ZW - LDR seriesIntelligent electromagnetic heat meterIs a kind of measuring heat transformation in the system of the heat released by the heat transfer fluid measurement instrument.It USES the high precision, high reliability as the flow measurement, the heat meter with high precision, high stability of the platinum thermal resistance temperature measurement, so that the heat table has very excellent performance measurement.Can be widely used in civilian residential quarters, office buildings and enterprises and institutions such as central heating, heating, air conditioning heat metering.

Second, the working principle:

ZW - LDR series intelligent electromagnetic heat meter according to the flow sensor in the system of traffic signals and matching temperature sensors for temperature signal, and the water flow through the time to calculate and display the system by the release or absorb heat.KWh, according to the quantity of heat in the form of the cumulative units, the biggest show eight.

Mathematical model for calculation:

Type: - the release of heat, kJ.

M - through the heat energy in the table the quality of the heat transfer fluid, kg/s.

- heat transfer loop outlet temperature of the inlet temperature and the corresponding heat transfer fluid than the enthalpy difference, kJ/kg;

T - time, s

Three, the main features:

1, the domestic liquid crystal display various parameters, but also according to user requirements to provide on-site display instrument.

2, all CMOS micro power circuit design, low power consumption system.

3, a communication module, which can realize remote communication.

4, with functions of valve control, remote control valve switch, is advantageous for the property charge management.

5, measuring mechanism has no moving parts, then never wear and tear, the measuring accuracy is not affected by using cycle.

6, can with the pump or host linkage, without refrigeration or heating, stop measurement, avoid system when not in use, because of small pipe flow and small temperature difference energy metering errors.

7, the integral design, convenient installation, safe and reliable.

8, heating and cooling.

Four, the electromagnetic heat meter technical parameters:

Converter technology parameters:

1, power supply: AC 220 v (110 vac ~ 245 vac) and 24 VDC;

2, power consumption: 20 w or less (auxiliary power consumption);

3, precision level: level 1 or level 2 (matching accuracy);

4, protection grade: IP65;

5, environmental temperature: A class;

6, temperature resolution: 0.01 ℃;

7, optional temperature measurement range: - 30 ℃ ~ 180 ℃;

8, temperature measurement range: 1 ℃ ~ 90 ℃;

9, flow readings (m3) : 9999999999 (10);

10, heat readings (Mwh) : 9999999999 (10);

11 units, heat: kJ, MJ, GJ, KWH, Mwh optional;

12, analog output: 4 ~ 20 ma DC / 600 load resistance (which can be switch between heat and flow parameters).

13, pulse output: zui 5000 hz frequency, pulse width 0.1 ms - 999.9 ms (can switch between heat and flow parameters).

14, communication: RS - 485, M (RS - 232 - BUS, HART and other optional).

Sensor technology parameters:

1, the nominal diameter: (~ DN1400mm;

2, nominal pressure: 0.6 MPa ~ 4 MPa;

3, the lining material: high temperature resistant rubber, PTFE, PFA, F46;

4, electrode materials: molybdenum stainless steel, hartz alloy, hartz alloy C B, tantalum, titanium, platinum/and iridium;

5, structure form, shape, size,

6, medium temperature: - 30 ℃ ~ 180 ℃;

7, connection mode: flange.

Temperature sensor technology parameters:

1, sensor types: PT1000;

2, installation method: protect casing;

3, temperature measuring range: - 50 ℃ ~ 200 ℃;

4, conductor length: 0.6 m to 15 m.

Five, the installation method:

1, the heating system should install a filter in the building.Before the heating system piping for cleaning, prevent the installation of pipeline into sundry intercepting heat meter.Sensor zui installed vertically (flow from bottom to top), in such a position, when the liquid flow, solids precipitation, and oil material rise, will adhere to the electrode.If mounted horizontally, must ensure that the pipe full of liquid, in order to avoid by air pockets and affect the measurement accuracy;

2, pipe diameter should be consistent with the sensor inner diameter, to avoid the phenomenon of throttling;

3, installation environment should be far away from the strong magnetic field equipment to prevent interference.(such as engine, transformer, radio transmitters, electrolytic cell or other cause electromagnetic interference places).

4, the electromagnetic heat meter can be installed in the inlet pipe can also be installed in the return pipe, convenient installation location should look-up table.Should not be less than 5 dn of straight pipe upstream of the sensor length, if have not fully open gate or upstream regulator, is connected to the gate valves and sensors of straight pipe length should be increased to 10 dn, downstream straight pipe length is generally not less than 3 dn can;

5, connection between the sensor and converter cable zui large length of 100;

6, the use of welding, the joint must be far away from the sensor, fight for sensor overheating or damage due to welding slag into lining;

7, the temperature sensor cable is 4 meters in length, the position of the return water temperature sensor and the position of the heat meter cannot exceed line length, such as more than can supply agreement;

Table 8, the electromagnetic heat grounding lines diameter should not less than 5.5 was, and as short as possible, and avoid and other equipment common grounding (recommend using a separate grounding).

Six, matters needing attention.

1, the axis of the measuring electrode must be similar to horizontal direction;

2, measuring the pipe must be completely filled with liquid.

3, flow meter in front of the need to have 5 * D for flow meter diameter (D) the length of the straight pipe, the rear need have 3 * D for flow meter diameter (D) the length of the straight pipe;

4, the direction of fluid flow and the direction of arrow flowmeter;

Five should have can be damaged by vacuum meter, the pipe lining, special attention should be paid;

6, near the flow meter should be no strong electromagnetic field;

7, shall have plenty of space, near the flowmeter to installation and maintenance;

8, if measuring pipeline vibration, the flowmeter should be fixed on both sides of bearing when measuring the mixed liquid of different medium hybrid point and the distance between the flow meter at least 30 x D for flow meter diameter (D) the length of the cleaning and maintenance for the convenience of the flowmeter, should install bypass pipe.

Seven, converter technology data:

The power supply

communication

85—265V,45—400Hz

dc

11—40V

Operation keys and display

touch-tone

Four film button can be set to choose all parameters, can also use a PC (RS232) of converter set programming;3 rows wide Angle of view, wide temperature, with backlit LCD display;Line 1 shows the flow value;Line 2 show that flow units;Line 3 shows total flow percentage, total quantity of forward, reverse, total difference, alarm, velocity of flow.

The magnetic key type

The selection of two magnetic key is used to display parameters and reset, use PC (RS232) on converter set programming;2 rows wide Angle of view, wide temperature, with backlit LCD display: line 1: the magnetic key choice: display flow percentage, total quantity of forward, reverse, total amount, total difference, alarm, velocity of flow.Line 2: display traffic.

Internal integrator

Total forward, reverse and total difference amount.

The output signal

One-way analog output

Complete isolation, load 600 d or less.When (20 ma);Cap: 0-21 ma optional, each lmA;Floor: 0-21 ma optional, each 1 ma;Forward and reverse flow output way of programming.

Two-way analog output

The lower limit for.or4mA, the other with one-way analog output.

The bidirectional pulse output

Two lines of the output corresponding to forward and reverse flow, 0 ~ 800 hz frequency, maximum of 1-800 hz optional, each IHz;Square-wave or selected pulse width, pulse width limit selected 2.5 s, every 1 ms;Passive isolation switch output transistor, can absorb 250 ma of current, voltage 35 v.

Two-way alarm output

Alarm (programming) high/low flow rate, air traffic control, fault state, positive, and reverse flow, analog outrange, pulse volume range, small pulse signal excision, output polarity optional;With isolation protection switch output transistor, can absorb the current of 250 ma, withstand voltage 35 v. (with pulse output isolation)

Digital communications


RS232,RS485,HART

Eight, the choice of the lining:

The lining material

The main performance

Medium temperature

Scope of application

—size

The separation type


Ptfe (F4)

Is a kind of plastic, stable chemical performance of boiling hydrochloric acid, sulfuric acid, strong alkali and a variety of organic solvents.

70℃

100℃ 150℃

(To be a special order)

1Strong, strong acid, alkali and other corrosive medium.

2Medium, health class.

Fep (F46)

withF4Above, abrasion resistance, resistance to negative pressure abilityF4。

Same as above


Poly fluoro ethylene (Fs)

For maximum temperature was lower than those of ptfe, but the cost is low.

80℃


Poly (neoprene

1And have very good elasticity, high pull force, wear-resisting performance is good.2, generally low concentration acid resistance, alkali, salt medium corrosion, oxidation of medium corrosion resistance.

80℃ 120℃

(To be a special order)

Water, sewage and mud pulp weak up to wear and tear.

Polyurethane rubber

1Strong, wear-resisting performance.

2And poor corrosion resistance.

80℃

Neutral strong wear of slurry, coal slurry and mud

Nine, reference flow range: import protection flange and the choice of grounding flange ring (or ground) :

Orchid species

optimum with van wai

Grounding the flange ring (or ground)

Non-conductors is suitable for pipeline, such as plastic pipe, but has the grounding electrode sensor doesn't need.

Import protection flange

When the medium has strong wear.

Ten, selection of code:

model

CAL

(In the wei and control)

ZW-LDR

15-2600



Code name

Type of installation


Y

one-piece

F

Split type


Code name

Converter model

ZA

circular

ZB

square


Code name

The output signal

I.4

4~20mA

f

frequency 1KHz

Rs

Serial communication (485)

C

Control the output


Code name

Explosion-proof requirements

N

No explosion-proof

EX

Explosion-proof (only applicable to split type)


Code name

Medium temperature

T1

65 or less℃

T2

120 or less℃

T3

180 or less℃ (only applicable to split type)


Code name

Lining material

NE

Neoprene (65 or less℃)

PTFE

Ptfe (189 or less℃)

PVC

Polyvinyl chloride (70 or less℃)


Code name

The electrode material

316L

Stainless steel

HC

Hartz alloyC

HB

Hartz alloyB

Ti

titanium

Ta

tantalum

Eleven, design and ordering information:

1, products such as designated models to standard, please live in wei and control advisory prices, details!

2, if not specified product specifications, please put the working condition of requirements, design drawings, technical specifications, fax or email to us.

3, product orders for parameters: size (DN), nominal pressure (Mpa), temperature (℃), the heat range (KWH, Mwh).

4, offer confirmation: the company provide price list and technical standard specifications to customers to confirm, in the technical aspects to confirm before you draw up a contract.

5, quality requirements, quality standards, the supplier is responsible for the quality conditions: according to the relevant state quality standards.

After-sales service commitment:

1, our company sold by wei electromagnetic heat meter products appear quality problem, within twelve months for free maintenance.

2, the warranty period, any quality problems such as the products of our company, my company is responsible for free repair or replacement.

3, the warranty period, such as user improper use, damaged products, my company is responsible for the maintenance, charge damage parts cost.

4, after the warranty period appear quality problem, my company is responsible for the maintenance, charge damage parts cost.

5, such as user need to my company site services, to users in the province I company service personnel to reach the site within 12 hours, fujian association of foreign languages and user reach the site within 48 hours.


Browse:
Return To The Top

分享到: